FIRE EXT CIRCUIT BREAKER WILL NOT STAY CLOSED (cont)
MULTIMETER DOES NOT INDICATE 28 VDC WITH NO.  1 ENGINE FIRE HANDLE OUT AND FIRE EXT AGENT SWITCH AT BOTTLE NO.  1 (cont)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  519    520    521    522    523  524  525    526    527    528    529  
TM 55-1520-240-T 12-3.6  MULTIMETER DOES NOT INDICATE 28 VDC WITH NO.  1 ENGINE FIRE HANDLE OUT AND FIRE EXT AGENT SWITCH AT BOTTLE NO.  1 12-3.6 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Aircraft Electrician (2) Applicable Configurations: All References: TM 55-1520-240-23 Tools: Electrical Repairer's Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Electrical Power On Materials: Hydraulic Power Off None GO TO NEXT PAGE 12-62  Change 23