CABLE  DOES  NOT  REEL  IN  WHEN  WINCH  IS  CONTROLLED  BY WINCH  GRIP  AT  STA  502  RECEPTACLE (cont)
28VDC NOT MEASURED AT STA 340 CABLE CUTTER RECEPTACLE WHEN HOIST/CARGO HOOK PANEL CABLE CUTTER SWITCH SET TO ON

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  606    607    608    609    610  611  612    613    614    615    616  
TM  55-1520-240-T 14-1.12  CABLE  DOES  NOT  REEL  OUT  WHEN  WINCH  IS  CONTROLLED  BY WINCH  GRIP  AT  HOIST  OPERATOR  STATION FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel Required: 68F10  Aircraft  Electrician 68F20  Aircraft  Electrician References: TM   55-1520-240-23 Equipment Condition: TM   55-1520-240-23: Battery Connected Electrical Power On Hydraulic Power On 14.1-12 14-32 END  OF  TASK