  700    701    702    703    704  705  706    707    708    709    710  
TM 55-1520-240-T 15-5.5.1  ENGINE HYDRAULIC STARTING SYSTEM OPERATIONAL CHECK (Continued) 15-5.5.1 TASK RESULT MOTOR NO.  2 ENGINE 7. On the FADEC panel, set and hold ENG START The NO.  2 ENGINE 2 N1 tachometer (9) must indicate 10 switch (7) to 2. to 15% N1 as starter motors engine.  If the engine does not motor, go to task 15-5.6.1. 8. Release the ENG START switch (7) to its center The NO.  2 ENGINE (9) indication must decrease to 0% position.   N1.  If the tachometer indication does not decrease or the engine continues to motor, go to task 15-5.7. FOLLOW-ON MAINTENANCE: TM 55-1520-240-23: Battery disconnected. Electrical power off. Hydraulic power off. END OF TASK Change 23  15-97