CROSSFEED FUEL VALVE LIGHT DOES NOT COME ON, VALVE OPERATION NORMAL (cont)
CROSSFEED  FUEL  VALVE  HANDLE  IS  NOT  AT  CLSD WITH  CROSSFEED  FUEL  VALVES  SWITCH  AT  CLOSE  (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
TM   55-1520-240-T 10-1.16  CROSSFEED  FUEL  VALVE  HANDLE  IS  NOT  AT  CLSD WITH  CROSSFEED  FUEL  VALVES  SWITCH  AT  CLOSE FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel    Required: 68F20   Aircraft   Electrician References: TM    55-1520-240-23 Equipment   Condition: TM   55-1520-240-23: Battery    Connected Electrical  Power  On Hydraulic   Power   Off 10-1.16 10-32