LIST  OF  TABLES ELECTRONIC SEQUENCE UNIT (ESU) TROUBLESHOOTING
APU  SYSTEMS   BITE  INDICATION  FAILURE  TABLE

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  708    709    710    711    712  713  714    715    716    717    718  
TM   55-1520-240-T 15-6  ELECTRONIC  SEQUENCE  UNIT  (ESU) 15-6 15-6.1 15-6.1 ESU  COMPONENTS BITE 1 2 3 4 DECODED   BITE   INFORMATION M A I N    F U E L    V A L V E    S I G N A L    O U T    ( 1 4 % ) RESET START  FUEL  VALVE  &  EXCITER  SIGNAL  OUT  (5%) START   FUEL   VALVE   &   EXCITER   SIGNAL   OFF   (70%) 90%  RPM  SWITCH  ON READY  FOR  SERVICE  (90%  +  1.5  SEC.) PROCESSOR   BOARD   FAILURE SENSOR   /DATA   BOARD   FAILURE OVERTEMPERATURE OVERSPEED UNDERSPEED FAILURE  TO  START SHORTED   THERMOCOUPLE   PROBE   (WARNING) OPEN   THERMOCOUPLE PROCESSOR  SEQUENCE  FAIL NO   TEMP   DATA NO  SPEED  DATA C h a n g e    8 15-105