TM 55-1520-240-T 15-6.14 APU STARTS BUT SHUTS DOWN, ESU BITE INDICATES                     (OVERSPEED) 15-6.14 FAULT ISOLATION PROCEDURE INITIAL SETUP References: TM 55-1520-240-23 Applicable Configurations: TM 55-2835-203-23 All TM 55-4920-431-13 Tools: Aircraft Mechanic's Tool Kit, Equipment Condition: NSN 5180-00-323-4692 TM 55-1520-240-23 Electrical Repairer's Tool Kit, Battery Connected NSN 5180-00-323-4915 Electrical Power On APU Tester 161226-200 Hydraulic Power On APU Tester Connected Between ESU and Airframe Materials: Wiring.  All Tester Switches Set Down None Personnel Required: Aircraft Electrician Medium Helicopter Repairer GO TO NEXT PAGE Change 23  15-127