RELEASE  SW  FAIL  LIGHT  OR  GROUND  RELAY  ACTIVATE LIGHT NOT ON WHEN PILOT CARGO HOOK RELEASE SWITCH PRESSED  (Continued)
RELEASE   SW   FAIL   LIGHT   OR   GROUND   RELAY   ACTIVATE   LIGHT   NOT   ON   WHEN   HOIST 1 6 - 1 . 20 OPERATORS   CARGO   HOOK   RELEASE   SWITCH   PRESSED

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  798    799    800    801    802  803  804    805    806    807    808  
TM  55-1520-240-T 16-1.19  RELEASE  SW  FAIL  LIGHT  OR  GROUND  RELAY ACTIVATE  LIGHT  NOT  ON  WHEN  COPILOT’S  CARGO HOOK  RELEASE  SWITCH  PRESSED 16-1.19 FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable All Tools: Personnel Required: Configurations: 68F20    Aircraft    Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Electrical   Repairer’s   Tool   Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multimeter Materials: None Equipment Condition: T M    5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery    Disconnected Electrical  Power  Off Hydraulic   Power   Off END OF TASK 16-49