FLARE  COUNTER  SEQUENCES  FROM  30  TO  00 WHEN  DISP  CONT  PANEL  ARM  SAFE  SWITCH SET TO ARM (Continued)
ARM   LIGHT   DOES   NOT   COME   ON   WHEN   ARM   SAFE SWITCH   SET   TO   ARM   (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  841    842    843    844    845  846  847    848    849    850    851  
TM   55-1520-240-T 16-2.12   ARM   LIGHT   DOES   NOT   COME   ON   WHEN   ARM   SAFE   SWITCH   SET   TO   ARM 16-2.12 FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Electronic   Equipment   Tool   Kit, NSN    5180-00-064-5178 Multimeter Materials: None Personnel   Required: Avionics   Mechanic   (2) References: TM   9-1095-206-13   &   P TM   55-1520-240-23 Equipment   Condition: TM   55-1520-240-23: Battery    Connected Electrical   Power   On Hydraulic   Power   Off GO   TO   NEXT   PAGE 16-98 Change  12