• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CANNOT CYCLE THROUGH PILOT'S MODE SELECTION AT CCU OR PILOT'S THRUSTER GRIP HUD CONTROL SWITCH
CANNOT CYCLE THROUGH COPILOT'S MODE SELECTION AT CCU OR COPILOT'S THRUSTER GRIP HUD CONTROL SWITCH

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  913    914    915    916    917  918  919    920    921    922    923  
TM 55-1520-240-T 16-4.26 CANNOT CYCLE THROUGH PILOT'S DECLUTTER AT CCU OR PILOT'S THRUSTER GRIP HUD CONTROL SWITCH 16-4.26 FAULT ISOLATION PROCEDURE Personnel Required: Avionics Mechanic INITIAL SETUP Applicable Configurations: References: All TM 55-1520-240-23 TM 11-5855-300-23&P Tools: Electronic Equipment Tool Kit, Equipment Condition: NSN 5180-00-064-5178 TM 55-1520-240-23: Multimeter Battery Connected Electrical Power On Materials: None END OF TASK Change 18    16-175