TM 55-1520-240-T
4-4.10 ENGINE 2 STARTER ON LIGHT DOES NOT COME ON
4-4.10
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
Without 74
References:
Tools:
TM 55-1520-240-23
Electrical Repairer's Tool Kit,
Equipment Condition:
NSN 5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
GO TO NEXT PAGE
4-68 Change 17