TM 55-1520-240-T
4-6.7 ENGINE NO. 2 TRIM CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
4-6.7
,
DID CIRCUIT BREAKER OPEN
BEFORE ENGINE TRIM SWITCH
No
DID CIRCUIT BREAKER OPEN
WAS SET TO RPM INCREASE
WHEN ENGINE TRIM SWITCH IS
OR RPM DECREASE?
SET TO RPM INCREASE?
CHECK FOR GROUND ON RE-
MAINING WIRES ON TB18
TERM 6 IS GROUND PRESENT?
DISCONNECT COPILOT THRUST
GRIP PLUG. CHECK FOR
GROUND ON TB18 TERM 6. IS
GROUND PRESENT?
LOCATE GROUND FAULT WIRE
W639-316-22 OR W552-163-
22 BETWEEN CB 103CB5 AND
TB18. REPAIR OR REPLACE
WIRE AS REQUIRED.
REPLACE ENGINE NO. 2
TRIM CIRCUIT BREAKER
103CB5.
REPLACE COPILOT THRUST
GRIP.
REMOVE PILOT FLOOR PANEL.
DISCONNECT PILOT THRUST
GRIP PLUG 300P25. CHECK FOR
GROUND ON TB18 TERM 6. IS
REPLACE PILOT THRUST GRIP.
GROUND PRESENT?
YES
LOCATE GROUND FAULT ON
WIRE W696-52-22 OR W696-
47-22 BETWEEN RECEPTACLES
300J25 AND 300J26 AND
TB18. REPAIR OR REPLACE
WIRE AS REQUIRED.
OPEN RIGHT ELECTRICAL COM-
PARTMENT. DISCONNECT WIRE
DISCONNECT PLUG 103P2
W592-41-22 FROM RELAY
FROM NO. 2 ENGINE CONTROL
103K2 TERM B2, CHECK FOR
BOX 103A2. CHECK FOR
GROUND ON WIRE. IS GROUND
GROUND ON PLUG 103P2 PIN B
PRESENT?
IS GROUND PRESENT?
RECONNECT WIRE W592-41-22
TO RELAY 103K2. REMOVE CO-
PILOT FLOOR PANEL. DISCON-
NECT COPILOT THRUST GRIP
PLUG 300P25, SET PILOT NO. 1
& NO. 2 ENGINE SWITCH TO
RPM DECREASE. CHECK FOR
GROUND ON TB18 TERM 13. IS
GROUND PRESENT?
CONNECT COPILOT THRUST
GRIP PLUG. REMOVE PILOT
FLOOR PANEL. DISCONNECT Pl-
LOT THRUST GRIP PLUG
300P25. SET COPILOT NO. 1 &
NO, 2 ENGINE SWITCH TO RPM
DECREASE. CHECK FOR
GROUND ON TB18 TERM 13. IS
GROUND PRESENT?
REPAIR OR REPLACE COPILOT
THRUST GRIP.
REPAIR OR REPLACE PILOT
THRUST GRIP.
OPEN RIGHT ELECTRICAL COM-
PARTMENT. DISCONNECT WIRE
W592-28-22 FROM RELAY
103K2 TERM X 1. CHECK FOR
NO
REPLACE RELAY 103K2
GROUND ON WIRE. IS GROUND
PRESENT?
LOCATE GROUND FAULT ON
WIRE W592-28-22, W639-325-
22, W696-49-22 OR W696-44-
22 BETWEEN RELAY 103K2,
TB18 AND RECEPTACLES
300J25 AND 300J26. REPAIR
OR REPLACE WIRE AS RE-
QUIRED,
REPLACE NO. 2 ENGINE CON-
TROL BOX 103A2.
LOCATE GROUND FAULT ON
WIRE W592-41-22 BETWEEN
RELAY 103K2 AND PLUG
103P2. REPAIR OR REPLACE
WIRE AS REQUIRED.
GO TO NEXT PAGE
Change 5
4-135