TM 55-1520-240-T4-6.10 NO. 1 ENGINE POWER TURBINE LEVER DOES NOT MOVE OR MOVES BUT DOES NOT CONTACT STOP (Continued)4-6.1NOSET EMERG ENG TRIM 1AUTO/MANUAL SW TO AUTO.CHECK FOR CONTINUITY BE-DISCONNECT CONTROL BOXYESTWEEN PLUG 103P1 PIN P ANDCHECK FOR GROUND ON PLUGPLUG 103P1 . CHECK FOR 115RELAY 103K4 TERM B3. IS CONTl-YES103P1 PIN L. IS GROUNDVAC BETWEEN PINK ANDNUITY PRESENT?PRESENT?GROUND. IS 115 VAC PRESENT?NOLOCATE OPEN IN WIRE W591-56-22 BETWEEN PLUG 103P1 ANDRELAY 103K4. REPAIR OR RE-PLACE WIRE AS REQUIRED.IREMOVE EMERG ENG TRIMLOCATE OPEN IN WIRE W557-PANEL FROM CONSOLE CHECK831-22, W645-320-22 OR W591-FOR 115 VAC AT ENG 1 SWITCHYES66-22 BETWEEN SWITCH 103S1103S1 TERM 3. IS 115 VACAND PLUG 103P1 . REPAIR OR RE-PRESENT?PLACE WIRE AS REQUIRED.CHECK FOR 115 VAC AT SWITCHREPLACE EMERG ENG TRIM 1103S1 TERM 2. IS 115 VACYESAUTO/MANUAL SWITCH ONPRESENT?EMERG ENG TRIM PANEL.I CHECK FOR 115 VAC AT NO.1LOCATE OPEN IN WIRE W550-ENG TRIM AND TIMER CIRCUITYES178-22, W645-305-22 OR W557-BREAKER 103 CB1 . IS 115 VAC826-22. REPAIR OR REPLACEPRESENT?WIRE AS REQUIRED.REPLACE 103CB1 CIRCUITBREAKER.103P1 AND FUSELAGE GROUND.REPAIR OR REPLACE WIRE ASREQUIRED.YESGO TO NEXT PAGE4-146Change 11