TM 55-1520-240-T4-6.11 NO. 1 ENGINE FUEL CONTROL POINTER DOES NOT MOVEOR MOVES BUT STOPS OUTSIDE OF 13° TO 21°ON PROTRACTOR (DECREASE SELECTED) (Continued)4-6.11HOLD PILOTS NO. 1 AND NO.2 TRIM SWITCH AT DEC OPENRIGHT ELECTRICAL COMPART-.MENT CHECK FOR 28 VDCBETWEEN RELAY 103K2 TERMA2(+) AND GROUND 1S28VDC PRESENT?CHECK FOR 28 VDC BETWEENRELAY 103K2 TERM A1 ( + )AND GROUND IS 28 VDCPRESENT/C HECK FOR GROUND ONRELAY 103K2 TERM X 2 ISGROUND PRESENT?YESHOLD PILOT’S NO. 1 AND NO.2 TRIM SWAT DEC. CHECKFOR 28 VDC BETWEEN RELAY103K2 TERMX1 (+) ANDGROUND IS 28 VDC PRESENT?LOCATE OPEN IN WIRE W59252-22 BETWEEN RELAY 103K2AND RELAY 103K1 REPAIR ORREPLACE WIRE AS REQUIREDREPLACE RELAY 103K2RELEASE SW DISCONNECTELECTRICAL POWERDISCONNECT PLUG 103P1FROM CONTROL BOX. CHECKFOR CONTINUITY BETWEENPLUG 103P1 PIN 8 AND RELAY103K2 TERM A2 ISCONTINUITY PRESENT?LOCATE OPEN IN WIRE W591-67-22 BETWEEN PLUG 103P1AND RELAY 103K2 REPAIR ORREPLACE WIRE AS REQUIREDLOCATE OPEN IN WIRE W591-GD132F20 BETWEEN RELAY103K1 AN D GROUND MODULEGD173 REPAIR OR REPLACEOPEN LEFT ELECTRICAL COM-PARTMENT CHECK FORGROUND ON RELAY 103K1TERM A3 IS GROUNDPRESENT?CHECK FOR GROUND ON PLUG103P1 PINA IS GROUNDPRESENT?LOCATE OPEN IN WIRE W591-2522 BETWEEN PLUG 103P1AND RELAY 1O3K1 REPAIR ORREPLACE WIRE AS REQUIREDCHECK FOR CONTINUITYBETWEEN PLUG 103P1 PIN AAN ORE LAY 103K1 TERM A2 ISCONTINUITY PRESENT?REPLACE NO 1 CONTROL BOXREPLACE RELAY 103K1GO TO NEXT PAGE4-152Change 1