TM 55-1520-240-T4-6.19 NO. 1 ENGINE FUEL CONTROL POINTER DOES NOT MOVE WHEN EMERGENCY ENGINE TRIM 1 SWITCH SET TO DEC4-6.19FAULT ISOLATION PROCEDUREINITIAL SETUPPersonnel Required:Applicable Configurations:Aircraft Electrician (2)Without 74References:Tools:TM 55-1520-240-23Electrical Repairer's Tool Kit,Equipment Condition:NSN 5180-00-323-4915TM 55-1520-240-23:MultimeterBattery ConnectedMaterials:Electrical Power OnNoneHydraulic Power OffGO TO NEXT PAGE4-170 Change17