Order in Print
4-12.28 DECU CODE F7
4-12.30 DECU CODE F9
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
462
463
464
465
466
467
468
469
470
471
472
Change 17 4-299
TM 55-1520-240-T
4-12.29
DECU CODE F8
4-12.29
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable
Configurations:
Aircraft Electrician
With
74
Aircraft
Powerplant
Repairer, Rotary-Wing Aviator
Tools:
References:
Electrical Repai
rer's Tool Kit,
TM 1-2840-265-23, TM 55-1520-240-10
NSN 5180-
00-323-4915
TM 55-1520-240-23
Powerplant
Repairer's Tool Kit,
Equipment Condition:
NSN 5180-
00-323-4944
TM 55-1520-240-23:
Multimeter
Battery Disconnected
Materials:
Electrical Power Off
None
Hydraulic Power Off
NOTE: Information
in () applies to DECU NO. 2.
END OF TASK