TRANSMISSION DEBRIS SCREEN INDICATOR IS ALL BLACK WHEN GND SWITCH IS SET TO TEST (Continued)
6-2.12 XMSN CHIP DET (WITHOUT 74 ) XMSN CHIP DETR (WITH 74 ) CAPSULE DOES NOT COME ON WHEN FORWARD TRANSMISSION CHIP DETECTOR SHORTED
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
566
567
568
569
570
571
572
573
574
575
576
TM 55-1520-240-T
6-2.11 FWD TRANSMISSION DEBRIS SCREEN INDICATOR DOES NOT
CHANGE TO BLACK-AND-WHITE FAN DISPLAY WHEN
DEBRIS SCREEN SHORTED
6-2.11
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
67U10 Medium Helicopter Repairer
68F20 Aircraft Electrician
Applicable Configurations:
All
References:
TM 55-1520-240-23
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multi meter
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Materials:
None
D 1 4 5 - 1 1 6 8 0 - S P A
END OF TASK