Home
Download PDF
Order CD-ROM
Order in Print
XMSN CHIP DET (WITHOUT 74 ), XMSN CHIP DETR (WITH 74 ) CAPSULE DOES NOT COME ON WHEN COMBINING TRANSMISSION CHIP DETECTOR SHORTED (CONT)
6-2.17 LEFT COMB TRANSMISSION DEBRIS SCREEN INDICATOR DOES NOT CHANGE TO BLACK-AND- 6-2.17 WHITE FAN DISPLAY WHEN DEBRIS SCREEN SHORTED
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
574
575
576
577
578
579
580
581
582
583
584
TM 55-1520-240-T
6-2.16 RH COMB TRANSMISSION DEBRIS SCREEN INDICATOR
6-2.16
DOES NOT CHANGE TO BLACK-AND-WHITE FAN
DISPLAY WHEN DEBRIS SCREEN SHORTED
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required
:
67U 10 Medium Helicopter Repairer
68F20 Aircraft Electrician
Applicable Configurations
:
All
References:
TM 55-1520-240-23
Tools
:
Electrical Repairer's Tool Kit,
NSN
5180-00-323-4915
Equipment Condition
:
Multimeter
TM 55-1520-240-23:
Battery Connected
Materials
:
Electrical Power On
None
Hydraulic Power Off
END OF TASK
6-74