FLIGHT CONTROL HYDRAULIC SYSTEM OPERATIONAL CHECK (Continued) - TM-55-1520-240-T-1_677
7 - 1 . 6 I N D I C A T I N G B U T T O N O N F L I G H T C O N T R O L H Y D R A U L IC PRESSURE OR RETURN FILTER IS EXTENDED
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
614
615
616
617
618
619
620
621
622
623
624
TM 55-1520-240-T
7-1.5 ILCA JAM SENSOR BUTTON EXTENDED
7-1.5
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
References:
Applicable
Configurations:
TM 55-1520-240-23
All
Equipment Condition:
Tools:
TM 55-1520-240-23
Aircraft
Mechanic's Tool Kit
Battery Disconnected
NSN
5180-00-323-4692
Electrical Power Off
Multimeter
Hydraulic Power Off
General Safety Instructions:
Materials:
None
WARNING
Keep hands and feet away
Personnel
Required:
from flight controls. Moving
67U20
Medium Helicopter Repairer
controls can cause serious
injury.
END OF TASK