UTILITY PRESS OR UTILITY RTN FILTER CHANGE LIGHT IS ON (Continued)
UTILITY PUMP FAULT LIGHT IS ON (CONTINUED)
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
685
686
687
688
689
690
691
692
693
694
695
TM 55-1520-240-T
7-2.13 UTILITY PUMP FAULT LIGHT IS ON
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
A ll
T o o k:
Electrical Repairer’s Tool Kit.
NSN
5180-00-323-4915
Aircraft Mechanic’s Tool Kit,
NSN
5180-00-323-4692
Multi meter
Materials:
N o ne
Personnel Required:
Medium Helicopter Repairer
Aircraft Electrician
References:
TM 55-1520-280-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power On
7-2.13
7-100 Change 6