RAMP CONTINUES TO CLOSE AS CARGO DOOR IS EXTENDING
RAMP EMERG CONT CIRCUIT BREAKER DOES NOT STAY CLOSED
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
727
728
729
730
731
732
733
734
735
736
737
TM 55-1520-240-T
7-3.12 RAMP
CREEPS
WITH RAMP CONTROL VALVE HANDLE AT STOP7-
7-3.12
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
References:
Applicable Configurations:
TM 55-1520240-23
All
Equipment Condition:
Tools
:
TM 55-1520-240-23:
Aircraft Mechanic's Tool Kit,
Battery Connected
NSN
5180-00-323-4692
Electrical Power On
Multimeter
Hydraulic Power On
Materials:
None
Personnel Required
:
Helicopter Repairer
CHECK RAMP ACTUATORS. ARE
EITHER OF THE ACTUATORS
NO
REPLACE RAMP CONTROL
HOT OR UNUSUALLY NOISY?
YES
REPLACE SUSPECT RAMP AC-
TUATOR.
END OF TASK
Change 14 7-138.1