TM 55-1520-240-T7-8.5 APU DOES NOT MOTOR7-8.5FAULT ISOLATION PROCEDUREINITIAL SETUPApplicable Configurations:AllTools:Electrical Repairer’s Tool Kit,NSN 5180-00-323-4915MultimeterHydraulic Power SourceMaterials:NonePersonnel Required:68F20 Aircraft Electrician67U10 Medium Helicopter RepairerReferences:TM 55-1520-240-23Equipment Condition:TM 55-1520-240-23:Battery ConnectedElectrical Power OnHydraulic Power Off90 x 54D145-11876-SPAGO TO NEXT PAGE7-216