INTEGRATED LOWER CONTROL ACTUATOR (ILCA) FAILS TEST 9 (EXTENSIBLE LINK CENTERING SPRINGS TEST (SPARE))
INTEGRATED LOWER CONTROL ACTUATOR (ILCA) FAILS TEST 12 VALVE JAM INDICATOR TEST (ALL))
TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
813
814
815
816
817
818
819
820
821
822
823
TM 55-1520-240-T
7-9.9 INTEGRATED LOWER CONTROL ACTUATOR (ILCA)
FAILS TEST 10 (PROOF PRESSURE TEST (ALL))
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanic’s Tool Kit,
NSN
5180-00-323-4692
Multimeter
Materials:
None
Personnel Required:
68H20 Aircraft Pneudraulics Repairer
References:
TM 55-1520-240-23
Equipment Condition:
Visual Check of Integrated Lower Control Ac-
tuator (ILCA) Performed (Task 7-9.2)
7-9.9
45 x 54
d145-12467-SPA
END OF TASK