NO. 1 OR NO. 2 ENGINE EMERGENCY POWER LIGHTS WILL NOT COME ON WHEN PRESSED TO TEST 8-5.4 (Continued)
NO. 1 ENGINE PTIT INDICATOR DOES NOT INDICATE IN GREEN BAND (Continued) - TM-55-1520-240-T-2_156
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
112
113
114
115
116
117
118
119
120
121
122
TM 55-1520-240-T
8-5.5
NO. 1 ENGINE PTIT INDICATOR DOES NOT INDICATE IN GREEN BAND
8-5.5
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
Without
74
Aircraft
Powerplant
Repairer
Tools:
References:
Electrical Repairer's Tool Kit,
TM 55-1520-240-23
NSN
5180-00-323-4915
TM 55-2840-254-23
Aircraft
Powerplant
Repairer's Tool Kit
Equipment Condition:
NSN
5180-00-323-4944
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Materials:
Hydraulic Power On
None
No. 1 Engine Work Platform Open
No. 1 Engine Upper and Lower Access Covers
Open