TM 55-1520-240-T
8-5.8 NO. 1 OR NO. 2 ENGINE EMERGENCY POWER FLAG INDICATOR WILL NOT RESET TO BLACK, FLAG RESET SWITCH AT RESET
8-5.8
FAULT ISOLATION PROCEDURE
INITIAL SETUP
References:
Applicable Configurations:
TM 55-1520-240-23
Without 74
Equipment Condition:
Tools:
TM 55-1520-240-23:
Electrical Repairer's Tool Kit,
Battery Connected
NSN 5180-00-323-4915
Electrical Power On
Multimeter
Hydraulic Power On
Materials:
Nose Access Door Open
None
Personnel Required:
Aircraft Electrician (2)
90X54
D145-11141-SPA
GO TO NEXT PAGE
8-90 Change 19