8-5.11 PILOT'S AND COPILOT'S EMERGENCY POWER LIGHTS DO NOT COME ON WHEN NO. 1 OR NO. 2 ENGINE PTIT INDICATION IS 890°C TO 910°C
8-5.11
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
Without 74
References:
Tools:
TM 55-1520-240-23
Electrical Repairer Tool Kit,
Equipment Condition:
NSN 5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power On
45X54
D145-11137-SPA
GO TO NEXT PAGE
8-96 Change 19