8-9.16
TM 55-1520-240-T
8-9.16 XMSN OIL PRESS CIRCUIT BREAKER DOES NOT STAY CLOSED
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials
None
Personnel Required:
68F20 Aircraft Electrician
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
G O T O N E X T P A GE
8 - 2 0 2