8-10.6
TM 55-1520-240-T
8 - 1 0 . 6 X M S N T E M P I N D I C A T O R P O I N T E R D O E S N O T I N D I C A T E
AMBIENT
TEMPERATURE
AT
SCAN
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
68F10 Aircraft Electrician
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23
Battery Connected
Electrical Power On
Hydraulic Power Off
8 - 2 2 8