TM 55-1520-240-T
8-10.9 NO. 1 OR NO. 2 ENG XMSN HOT (WITHOUT 74), ENG 1 OR ENG 2 XMSN HOT (WITH 74) CAPSULE DOES NOT COME ON DURING TEST
8-10.9
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician (2)
All
References:
Tools:
TM 5-1520-240-23
Electrical Repairer's Tool Kit,
Equipment Condition:
NSN 5180-00323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
GO TO NEXT PAGE