TM 55-1520-240-T
8-11.9 FUEL QUANTITY INDICATION WRONG WHEN FUEL QUANTITY SELECT SWITCH IS SET TO L AFT
8 11.9
FAULT ISOLATION PROCEDURE
INITIAL SETUP
References:
Applicable Configurations:
TM 55-1520-240-23
All
Equipment Condition:
Tools:
TM 55-1520-240-23:
Electrical Repairer Tool Kit,
Battery Connected
NSN 5180-00-323-4915
Electrical Power On
Multimeter
Hydraulic Power Off
Materials:
Right Forward Landing Gear Access Panel Open
None
Personnel Required:
Aircraft Electrician (2)
GO TO NEXT PAGE