TM 55-1520-240-T
8-11.15
R FUEL LOW (WITHOUT 74), R FUEL LVL (WITHOUT 74) WARNING CAPSULE ON WHEN R MAIN FUEL TANK IS FULL
8-11.15
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician (2)
All
References:
Tools:
TM 55-1520-240-23
Electrical Repairer Tool Kit,
Equipment Condition:
NSN 5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
GO TO-NEXT PAGE
8-290 Change 19