TM 55-1520-240-T8-11.15R FUEL LOW (WITHOUT 74), R FUEL LVL (WITHOUT 74) WARNING CAPSULE ON WHEN R MAIN FUEL TANK IS FULL8-11.15FAULT ISOLATION PROCEDUREINITIAL SETUPPersonnel Required:Applicable Configurations:Aircraft Electrician (2)AllReferences:Tools:TM 55-1520-240-23Electrical Repairer Tool Kit,Equipment Condition:NSN 5180-00-323-4915TM 55-1520-240-23:MultimeterBattery ConnectedMaterials:Electrical Power OnNoneHydraulic Power OffGO TO-NEXT PAGE8-290 Change 19