INDICATORS DO NOT TURN BLACK AND WHITE WITH GND TEST SWITCH AT TEST (Continued)
FILTER CHANGE AND PUMP CHANGE LIGHTS DO NOT COME ON WHEN PRESSED
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
370
371
372
373
374
375
376
377
378
379
380
TM 55-1520-240-T
8-14.8 INDICATOR WILL NOT TURN ALL BLACK WITH
GND TEST SWITCH AT RESET
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
Materials:
None
Personnel Required:
68F20
Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Battery Connected
Electrical Power On
Hydraulic Power Off