ENGINE NO. 1 FUEL FLOW CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
ENGINE NO. 2 FUEL FLOW CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
392
393
394
395
396
397
398
399
400
401
402
TM 55-1520-240-T
8-16.5 ENGINE NO. 2 FUEL FLOW
CIRCUIT BREAKER
WILL NOT STAY CLOSED
8-16.5
FAULT
ISOLATION PROCEDURE
INITIAL
SETUP
Personnel Required:
Applicable
Configurations:
Aircraft Electrician (2)
All
References:
Tools:
TM 55-1520-240-23
Electrical Repairer Tool Kit,
Equipment Condition:
NSN
5180-00-323-4915
TM 55-1520-240-33:
Multimeter
Battery Disconnected
Materials:
Electrical Power Off
None
Hydraulic Power Off