TM 55-1520-240-T9-1.4DC POWER SYSTEM OPERATIONAL CHECKINITIAL SETUPApplicable Configurations:AllReferences:TM 55-1520-240-23Tools:28 VDC External Power SourceEquipment Condition:TM 55-1520-240-23:Materials:Battery ConnectedNoneElectrical Power OffHydraulic Power OffPersonnel Required:Visual Check of Dc Power SystemAircraft Electrician (2) Performed (Task 9-1.3)TASKRESULTCHECK CIRCUIT BREAKERS1.Checkthat following circuit breakers onIf any circuit breaker (1 through 9) is open, closeNo. 1 pdpare closed:it.BATT CHGR (1)NO. 1 XFMR RECT (2)DC 1 CROSSTIE (3)NO. 1 DC BUS CONT (4)EXT PWR CONT (5)NO. 1 REV CUR CO (6)CAUTION PNL (7)ESS BUS CONT (8)ESS BUS FEEDER (9)2.Checkthat following circuit breakers onIf any circuit breaker (10, 11, 12, or 13) is open.No. 2 pdpare closed:closed it.NO. 2 XFMR RECT (10)DC2 CROSSTIE (11)NO. 2 DC BUS CONT(12)NO. 2 REV CUR CO (13)9-1.4GO TO NEXT PAGE9-10 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business