TM 55-1520-240-T
9-4.12 PILOT'S LANDING LIGHT WILL NOT RETRACT WITH PLT SLT CONT SWITCH
9-4.12
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician (2)
All
References:
Tools:
TM 55-1520-240-23
Electrical Repairer's Tool Kit,
Equipment Condition:
NSN
5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off