8-1.11
TM 55-1520-240-T
8-1.11 PILOTS OR COPILOTS ALTIMETER VIBRATOR
DOES NOT OPERATE
F A U L T I S O L A T I O N P R O C E D U RE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
M a t e r i a l s:
None
Personnel Required:
68F10 Aircraft Electrician
68F20 Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3 :
Battery Connected
Electrical Power On
Hydraulic Power Off
8-18