TM 55-1520-240-T
9-6.5 ANTICOLLISION LIGHT, TOP OR BOTTOM, DOES NOT FLASH OR DOES NOT FLASH 40-60
9 - 6 .5
TIMES/MINUTE
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
All
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Tools:
Electrical Repairers Tool Kit,
General Safety Instructions:
NSN 5180-00-323-4915
Multimeter
Materials:
Wait 10 minutes after power has been
None
disconnected before disconnecting an-
Personnel Required:
ticollision
Aircraft Electrician (2)
discharge
References:
injury.
TM 55-1520-240-23
light connector. High voltage
can occur, causing personnel
9-156
Change 2