TM 55-1520-240-T9-11.8 OVERHEAD PANEL LIGHTS OPERATIONAL CHECK9-11.8INITIAL SETUPReferences:ApplicableConfigurations:TM 55-1520-240-23.With 17Equipment Condition:Tools:TM 55-1520-240-23:NoneBattery ConnectedMaterials:Electrical Power OnNoneHydraulic Power OffOverhead Panel Lights Visual Check PerformedPersonnel Required:(Task 9-11.7)Aircraft ElectricianTASKRESULT1.Check that LIGHTING OVHD PNL circuit breaker (1)isIf OVHD PNL circuit breaker (1) is open, close it. If itclosed.opens again, go to task 9-11.9.2.Turn OVHD CSL lights control (2) from OFF throughAll control panels in overhead panel shall light dim andDIM to BRT.increase in brightness as control (2) is turned to BRT. Ifany panel is not lit, go to task 9-11.10. If panel brightnessdoes not increase as control is turned, replace OVHDCSL lights control.3.Turn OVHD CSL lights control (2) to OFF.All control panel lights in overhead panel shall go out. Ifnot, replace OVHD CSL lights control.Follow-on Maintenance:TM 55-1520-240-23:Battery DisconnectedElectrical Power OffEND OF TASK9-212.2 Change 19
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business