NO. 1 GAS PRODUCER TACHOMETER READS 0 PERCENT RPM WHEN NO. 1 ENGINE IS MOTORED (Continued)
N O . 2 G A S P R O D U C E R T A C H O M E T E R R E A D S 0 P E R C E N T R P M W H E N N O . 2 E N G I N E I S M O T O R E D
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
50
51
52
53
54
55
56
57
58
59
60
TM 55-1520-240-T
8-2.5
NO. 2 GAS PRODUCER
TACHOMETER
READS 0 PERCENT RPM WHEN NO. 2 ENGINE IS MOTORED
8-2.5
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
Without
74
References:
Tools
:
TM 55-1520-240-23
Electrical Repairer Tool Kit,
Equipment Condition:
NSN
5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power Off
None I
Hydraulic Power Off
D145-8314-SPA
90.54
GO TO NEXT PAGE
8-38 Change 19