TM 55-1520-240-T
9-18.11
MASTER CAUTION PANEL LIGHTS DO NOT GO BRIGHT
9-18.11
WHEN DOME SELECT SWITCH SET TO WHITE
FAULT ISOLATION PROCEDURE
Personnel Required:
INITIAL SETUP
68F10 Aircraft Electrician
68F20 Aircraft Electrician
Applicable Configurations:
All
References:
TM 55-1520-240-23
Tools:
Electrical Repairer's Tool Kit.
Equipment Condition:
NSN 5180-00-323-4915
TM 55-1520-240-23:
Multimeter
LTG Panel Lowered From Overhead Panel
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
END OF TASK
9-340