TM 55-1520-240-T9-18.11MASTER CAUTION PANEL LIGHTS DO NOT GO BRIGHT9-18.11WHEN DOME SELECT SWITCH SET TO WHITEFAULT ISOLATION PROCEDUREPersonnel Required:INITIAL SETUP68F10 Aircraft Electrician68F20 Aircraft ElectricianApplicable Configurations:AllReferences:TM 55-1520-240-23Tools:Electrical Repairer's Tool Kit.Equipment Condition:NSN 5180-00-323-4915TM 55-1520-240-23:MultimeterLTG Panel Lowered From Overhead PanelBattery ConnectedMaterials:Electrical Power OnNoneHydraulic Power OffEND OF TASK9-340