TM 55-1520-240-T
Change 24 16-215
16-5.8 READY TO FIRE LIGHT DOES NOT COME ON
16-5.8
FLARE
DISPENSER
READY TO FIRE
LDG GR
SW STATUS
LIGHT TO
ILLUMINATE
IN AIR
LDG GR
SW BYPASS
BYPASS
NORMAL
REMOTE BYPASS
SWITCH PANEL
LDG GEAR SW
STATUS LIGHT
READY TO FIRE
LIGHT
LDG GEAR
BYPASS LIGHT
WT0058
CMDS
01
02
CH
INHIBIT
FL
RWR
OFF
STBY
MAN
SEMI
AUTO
BYP
1
2
3
4
PRG
MWS
JMR
ENT
BIT
MODE
MANUAL
DISPENSE
J
E
T
T
I
S
O
N
A
B
C
D
E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
A
B
C
D
NO. 1 PDP
DCDU
CIRCUIT BREAKER
DCDU
ALE-47 J-BOX
147P33/J2
147P32/J1
EAPS/MEAPS
C/B PANEL
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Avionics Mechanic
Applicable Configurations:
All
References:
TM 55-1520-240-23
Tools:
Electronic Equipment Tool Kit,
Equipment Conditions:
NSN 5180-00-064-5178
TM 55-1520-240-23:
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
GO TO NEXT PAGE