TM 55-1520-240-T18-1.8 DATA LOADER MODULE INFORMATION DOES NOT LOAD INTO GPS SYSTEM18-1.8BUT NO ERROR MESSAGE APPEARS ON CONTROL DISPLAY UNIT (CDU)FAULT ISOLATION PROCEDUREINITIAL SETUPReferences:Applicable Configurations:TM 11-5826-308-12AllTM 55-1520-240-23Tools:Electrical Repairer's Tool Kit,Equipment Condition:NSN 5180-00-323-4915TM 55-1520-240-23:Multimeter, AN/USM-223,Battery ConnectedNSN 6625-00-999-7465Electrical Power OnHydraulic Power OffMaterials:NonePersonnel Required:Aircraft ElectricianEND OF TASK18-28 Change 18