Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
RH FUEL PUMP AUX FWD CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
RH FUEL PUMP AUX AFT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
74
75
76
77
78
79
80
81
82
83
84
TM 55-1520-240-T
10-2.15 RH FUEL PUMP AUX AFT
CIRCUIT BREAKER
WILL NOT STAY CLOSED
10-2.15
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
Aircraft Electrician (2)
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Side Acoustical Blanket Removed Between Sta
320 and 360
Right Aft Intertank Access Panel Open
10-68
Change 3
GO TO NEXT PAGE