TM 55-1520-240-T
1O-2.28 RIGHT SIDE AUX PRESS LIGHTI COMES ON WHEN RIGHT SIDE AFT AUX FUEL PUMPS SWITCH IS
10-2.28
SET TO ON
FAULT ISOLATION PROCEDURE
INITIAL SETUP
References:
Applicable Configurations:
TM 55-1520-240-23
All
Equipment Condition:
Tools:
TM 55-1520-240-23:
Electrical Repairers Tool Kit,
Battery Connected
NSN 5180-00-323-4915
Electrical Power On
Multimeter
Hydraulic Power Off
Side Acoustical Blanket Removed Between Sta
Materials:
None
320 and 360.
Right Aft Intertank Access Panel Open
Personnel Required:
Aircraft Electrician (2)
10-110
GO TO NEXT PAGE