Home
Download PDF
Order CD-ROM
Order in Print
CONT CENTER CIRCUIT BREAKER DOES NOT STAY CLOSED (cont) - TM-55-1520-240-T-3_273
CONTROL STICK AND PEDALS WILL NOT STAY CENTERED AFTER PILOTS CENTERING DEVICE RELEASE SWITCH RELEASED (cont)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
221
222
223
224
225
226
227
228
229
230
231
TM 55-1520-240-T
11-2.6 CONTROL STICK AND PEDALS WILL NOT STAY CENTERED
AFTER PILOT’S CENTERING DEVICE RELEASE SWITCH
RELEASED
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
Materials:
None
Personnel Required:
67U10 Medium Helicopter Repairer
68F20 Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:
Battery Connected
Electrical Power On
Hydraulic Power On