TM 55-1520-240-T11-3.19 NO 1 PITCH ILCA HAS ENGAGE TRANSIENT1 1 - 3 . 1 9F A U L T I S O L A T I O N P R O C E D U R EI N I T I A L S E T UPA p p l i c a b l e C o n f i g u r a t i o n s :A l lT o o l s:Electrical Repairer’s Tool Kit,NSN 5180-00-323-4915M u l t i m e t erM a t e r i a l s:N o neR e f e r e n c e s :T M 5 5 - 1 5 2 0 - 2 4 0 - 23T M 5 5 - 4 9 2 0 - 4 2 9 - 13E q u i p m e n t C o n d i t i o n:T M 5 5 - 1 5 2 0 - 2 4 0 - 23B a t t e r y C o n n e c t edElectrical Power OnH y d r a u l i c P o w e r OnT M 5 5 - 4 9 2 0 - 4 2 9 - 13AFCS Line Test Set 145G0009-1Prepared for UsePersonnel Required:3 5 K 1 0 A v i o n i c M e c h a n i c3 5 K 2 0 A v i o n i c M e c h a n ic1 1 - 9 2GO TO NEXT PAGE