LCT ACTUATOR CONTROL TRANSISTOR BVRNS OUT (cont) - TM-55-1520-240-T-3_414
AFT LCT INDICATOR DOES NOT SHOW EXTENSION OR RETRACTION IN MANUAL CONTROL 11-3.36 (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
360
361
362
363
364
365
366
367
368
369
370
TM 55-1520-240-T
11-3.36 AFT LCT INDICATOR DOES NOT INDICATE EXTEND OR RETRACT
DURING MANUAL CONTROL
11-3.36
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
38K10 Avionic Mechanic
35K20 Avionic Mechanic
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23
Battery Connected
Electrical Power On
Hydraulic Power Off