TM 55-1520-240-23.
TM 55-1520-240-T
11-3.61
BAROMETRIC ALTITUDE HOLD INOPERATIVE OR RESPONSE ERRATIC (RADAR ALTITUDE
11-3.61
HOLD OKAY)
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
Avionic Mechanic (2)
References:
TM 55-1520-240-23
TM 55-4920-429-13
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power On
TM 55-4920-429-13
AFCS Line Test Set 145G0009-1 Prepared
for Use
END OF TASK
11-184
Change 3