Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
CENTER WINDSHIELD DOES NOT GET WARM (Continued) - TM-55-1520-240-T-3_537
PILOT WSHLD ANTI ICE CONT CIRCUIT BREAKER WILL NOT STAY CLOSED
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
478
479
480
481
482
483
484
485
486
487
488
TM 55-1520-240-T
12-1.11 CENTER WINDSHIELD CONTINUES TO HEAT WHEN CTR
WINDSHIELD SWITCH IS AT OFF
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
Materials:
None
Personnel Required:
68F20 Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:
Battery Connected
Electrical Power On
Hydraulic Power Off
Nose Dynamic Absorber Removed
12-1.11
12-20
END OF TASK
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business