NO. 1 ENGINE FIRE HANDLE FIRE PULL/FUEL SHUTOFF CAPTION LIT (Continued)
NO. 2 ENGINE FIRE HANDLE FIRE PULL/FUEL SHUTOFF CAPTION LIT (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
497
498
499
500
501
502
503
504
505
506
507
TM 55-1520-240-T
12-2.7 NO. 2 ENGINE FIRE HANDLE FIRE PULL/FUEL SHUTOFF CAPTION LIT
12-2.7
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
All
References:
Tools:
TM 55-1520-240-23
Electrical Repairer's Tool Kit,
Equipment Condition:
NSN
5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
Cloth (E120)
Hydraulic Power Off
GO TO NEXT PAGE
12-40 Change 23