TM 55-1520-240-T
15-3.7 APU MOTORS BUT DOES NOT START, ESU BITE INDICATES
THEN
(FAILURE TO START)
15-3.7
FAULT ISOLATION PROCEDURE
INITIAL SETUP
TM 55-2835-205-23
Applicable Configurations:
Equipment Condition:
All
TM 55-1520-240-23
Tools:
Battery Connected
Aircraft Mechanic's Tool Kit,
Electrical Power On
NSN 5180-00-323-4692
Hydraulic Power Off
Electrical Repairer's Tool Kit,
General Safety Instructions:
NSN 5180-00-323-4915
Multimeter
Materials:
WARNING
None
Personnel Required:
All regulations and instructions for
Aircraft Electrician
handling fuels shall be strictly ob-
Medium Helicopter Repairer
served.
References:
TM 55-1520-240-23
GO TO NEXT PAGE
15-60 Change 23